Menu Close

Laboratory Decommissioning for Closures, Relocations, and Lease Exits

Boston-based, serving clients nationwide and internationally

Laboratory decommissioning is the documented process of clearing a laboratory of hazardous materials, contamination and equipment before the space is closed, relocated or returned to a landlord. Hingham Moving Services helps by planning the move around that work and moving or storing equipment once it has been cleared.

Your principal investigator or laboratory manager works with your environmental health and safety (EHS) office to remove or transfer hazardous materials, address contamination and document clearance. Hingham Moving Services plans its part around that work so equipment can be packed and moved once it is cleared.

Laboratory Decommissioning Responsibilities: Who Does What Before a Laboratory Is Vacated

As Cornell University EHS describes common practice, the principal investigator or laboratory manager is responsible for disposing of or transferring hazardous materials, the EHS office inspects and signs off, and the landlord or organization accepts the cleared space. Hingham Moving Services helps coordinate that work with the moving schedule and handles equipment relocation or storage.

Rensselaer’s laboratory decommissioning policy lists the usual triggers: leaving a laboratory space, relocating to a different space (even in the same building), ending the use of radioactive materials or radiation-producing equipment, and taking Class 3B or Class 4 lasers out of use. That is one university’s practice, not a law.

Alongside our laboratory relocation services, our laboratory decommissioning services support your team in five areas:

  • Planning the move around decommissioning requirements, starting with an on-site survey.
  • Coordinating the move around fume hood and ventilation cleaning, which is done by licensed vendors and the EHS office.
  • Timing packing and moving around chemical disposal, which is handled by licensed hazardous-waste vendors and the EHS office.
  • Moving cleared equipment to the new site or into bonded, climate-controlled storage.
  • Moving frozen samples in freezers that travel plugged in and powered, with the temperature of each freezer tracked for the whole trip.

Decommissioning Assessment, Planning and Step-by-Step Process

Start with your hazard inventory, lease requirements, and EHS procedures. Our part begins with an on-site survey of equipment, materials, access, and timing.

StepWork involvedWho handles it
1. Review requirementsNotify EHS and review the lease, licenses, and permits.Laboratory leadership and facilities
2. Inventory hazardsIdentify chemicals, biological and radioactive materials, compressed gases, and controlled substances.Laboratory staff and EHS
3. Survey the moveReview equipment, access, materials, and scheduling.Hingham Moving Services
4. Prepare the moving planConfirm equipment destinations and provide a clear, upfront moving quote.Hingham Moving Services, with the laboratory
5. Remove materialsTransfer or dispose of chemicals and biological materials.Laboratory and EHS office, with licensed hazardous-waste vendors
6. Decontaminate and clearAddress equipment and space contamination.Laboratory, EHS office, and licensed vendors, including for ventilation cleaning
7. Pack and transportPack cleared equipment and transport it on dedicated trucks.Hingham Moving Services
8. Deliver or storePlace equipment at the destination or move it into storage.Hingham Moving Services
9. Complete closeoutAssemble records and conduct the final walkthrough.Laboratory, EHS, and landlord or organization

Under Cornell University EHS practice, equipment used with radioactive materials must be surveyed and documented as contamination-free before movers handle it.

ANSI/ASSE Z9.11-2016, Laboratory Decommissioning, is the voluntary consensus standard that sets out stakeholder roles (principal investigator, EHS office, facilities and landlord) and the criteria for a decommissioning plan; the NIH summary of ANSI/ASSE Z9.11-2016 explains it. For the moving portion, see how to move a laboratory.

Lab Decontamination and Sign-Off for Equipment, Biosafety Cabinets and Fume Hoods

Before our crews pack equipment, any required lab decontamination and clearance is completed by licensed vendors and the EHS office. This means removing or inactivating hazardous residues so equipment can be handled, moved, or released.

EquipmentPreparation and clearanceOur role
Biosafety cabinetsEHS or the biosafety officer determines biosafety cabinet decontamination requirements with qualified specialists. Arrange post-move field certification.Move cabinets once cleared
Fume hoods and ductworkAppropriate contractors clean chemical residues; arrange performance testing after reinstallation.Help coordinate the move around cleaning done by licensed vendors
Freezers and cold roomsLaboratory staff determine sample destinations; retired units are emptied, defrosted, cleaned, and disinfected.Move freezers holding frozen specimens and cold-room contents
IncubatorsLaboratory staff empty and disinfect equipment.Move incubators; drain water-jacketed units for transport
Glove boxes, centrifuges, and benchtop equipmentLaboratory staff arrange hazard-appropriate cleaning and clearance.Move cleared equipment
Radioactive-use equipmentThe radiation safety officer arranges the required survey and release.Move equipment only after clearance

Your institution may require clearance tags, certificates, or testing records. We do not decontaminate equipment, perform ventilation cleaning, or issue clearance certificates.

For equipment that is potentially contaminated with blood or other infectious materials, OSHA’s Bloodborne Pathogens Standard addresses examination, necessary decontamination, and the identification of any remaining contamination before servicing or shipping.

For biosafety cabinet decontamination, the CDC’s BMBL 6th edition says a risk assessment decides whether and how a cabinet is decontaminated before it is relocated, and that a cabinet is tested each time it is moved. Field certification follows NSF/ANSI 49-2026 and should be done by an accredited field certifier.

At the new site, a few habits go a long way toward keeping a laboratory clean after a move.

Laboratory Chemical Inventory, Lab Packs and Lab Chemical Disposal

Your laboratory inventories its chemicals and decides which will be transferred to another laboratory, retained for use elsewhere, or disposed of. The inventory should include the associated safety data sheets. Your laboratory remains responsible for determining which discarded chemicals must be managed as hazardous waste.

Discarded chemicals become hazardous waste under the federal Resource Conservation and Recovery Act (RCRA). Lab chemical disposal is handled by licensed hazardous-waste vendors and the EHS office, which may use lab packs: drums in which small containers of compatible chemicals are packed with absorbent material for shipment to a permitted treatment, storage and disposal facility. Hingham Moving Services helps coordinate the move around that work but does not prepare lab packs or dispose of chemical waste.

Confirm these requirements with EHS:

Hingham Moving Services does not offer stand-alone chemical moving. Whether any chemicals travel as part of a full laboratory move is decided at the on-site survey.

Closure Documentation, Regulations and Scope Limits

RecordWho reviews or retains it
Chemical inventory and waste manifestsEHS; regulator on request
Decontamination certificates and applicable wipe-test resultsEHS and landlord
Biosafety cabinet decontamination and certification recordsEHS or biosafety officer
Radiation clearance surveyRadiation safety officer and applicable regulator
Equipment clearance tagsEHS, mover, and receiving party
Equipment moving or storage inventoryLaboratory and receiving site

Agree on acceptable evidence of turnover with the landlord as early as possible. EHS and the contractors performing the work supply clearance records, not us.

Radioactive materials, controlled substances, and select agents are closed out by the license or registration holder under their own rules (NRC or the Massachusetts Radiation Control Program, DEA, and the Federal Select Agent Program) before movers touch the equipment. Among OSHA’s laboratory standards, the Laboratory Standard (29 CFR 1910.1450) requires a written Chemical Hygiene Plan, as the OSHA Laboratory Standard fact sheet explains.

Estimates, Bound Pricing, and the 100% Guarantee

Your move starts with an on-site survey so we can review your equipment, access requirements, storage needs, and schedule. We then provide a free estimate with bound pricing, which means you may pay less than the quoted amount, but never more.

With decades of experience, our classroom-trained, in-house crews handle your equipment, and the same driver stays with your shipment from pickup through delivery. We do not subcontract the physical move. Our moving service insurance includes liability, workers’ compensation, and motor truck cargo coverage.

With our 100% guarantee, you do not pay until every part of your move is completed as promised in your moving agreement. Pricing and payment terms apply to the move itself, not to decontamination, disposal, or cleaning work done by licensed vendors.

What shapes the quote for the move: the volume and type of equipment, frozen samples, distance, storage, building access, and scheduling around decontamination and clearance. For more on what drives the price, see laboratory relocation cost.

Frequently Asked Questions About Laboratory Decommissioning

Allow several months. Cornell’s lab decommissioning process notes that substantial advance notice and work are generally required. Our survey helps coordinate moving dates with your clearance schedule.

University EHS procedures commonly restrict this work to authorized, trained personnel. Our crews move equipment after the lab or license holder has cleared it.

Your laboratory decides whether each sample is transferred, moved, or disposed of. For frozen biological transport, freezers travel plugged in and powered on trailers with 110 V to 220 V outlets, backed by a redundant backup generator system and backup freezers on board, with the temperature of each freezer tracked for the whole trip. Overnight and 72-hour delivery options are available.

Typically, yes. The vacated space still needs closeout, and equipment needs applicable clearance. Certain instruments also require testing or certification before use at the destination. Hingham Moving Services moves the cleared equipment to the new laboratory.

Start Your Laboratory Decommissioning With an On-Site Survey

For help coordinating your laboratory decommissioning with a move, contact Hingham Moving Services for an on-site survey and free estimate. We are Massachusetts-based, with offices in Hanover, Woburn, Wellesley, and Millis, and move laboratories locally, long-distance across the 48 contiguous states, and internationally.